This is a visual explainer based on the Wikipedia article on Capacity Factor. Read the full source article here. (opens in new tab)

Gauging the Grid

Understanding the crucial metric that defines the real-world performance of power plants, from potential to actual output.

What is It? 👇 Explore Data 📊

Dive in with Flashcard Learning!


When you are ready...
🎮 Play the Wiki2Web Clarity Challenge Game🎮

Defining Capacity Factor

The Core Concept

The net capacity factor is a unitless ratio that measures the actual electrical energy a power plant produces over a period against the theoretical maximum it could have produced. This theoretical maximum is based on the plant running continuously at its full nameplate capacity for the entire period. It's a key performance indicator for any electricity-generating facility.

Universal Applicability

This metric can be calculated for any type of power plant, whether it's a traditional fuel-consuming station or one that harnesses renewable energy like wind, solar, or hydro. This allows for a standardized comparison of the operational performance of different electricity production technologies, revealing how much of their potential they actually realize in practice.

Key Influencing Variables

A plant's capacity factor is influenced by numerous variables. It can never exceed the availability factor, which accounts for downtime from maintenance (scheduled or unscheduled) and reliability issues. Other critical determinants include the plant's design, its geographical location, the type of energy source (e.g., consistent fuel vs. intermittent weather), and external pressures like regulatory constraints or market forces.

The Calculation

The Fundamental Equation

The capacity factor (CF) is calculated using a straightforward formula:

CF = Et / (Pn × t)

  • Et: The total electrical energy produced during the time period (e.g., in Megawatt-hours, MWh).
  • Pn: The nameplate capacity, or maximum rated power output of the plant (e.g., in Megawatts, MW).
  • t: The total duration of the time period (e.g., in hours).

A Practical Example

To illustrate, consider a power plant with a nameplate capacity of 1 Megawatt (MW).

If, in a single hour, this plant produces 0.5 Megawatt-hours (MWh) of electricity, its capacity factor for that hour would be:

CF = 0.5 MWh / (1 MW × 1 h) = 0.5

This result of 0.5 is equivalent to a 50% capacity factor, meaning the plant generated half of its maximum possible output during that hour.

Real-World Examples

Nuclear Power Plant

Nuclear plants typically exhibit very high capacity factors, as they are designed for continuous baseload operation. For instance, the Palo Verde Nuclear Generating Station in the U.S., with a nameplate capacity of 3,942 MW, generated 31,200,000 MWh in 2010. This resulted in an impressive capacity factor of 90.4%. The primary downtime is for scheduled refueling and maintenance, which occurs roughly every 18 months per reactor.

Wind Farm

Wind farms are subject to the variability of wind. The Danish offshore farm Horns Rev 2 (209.3 MW capacity) achieved an average capacity factor of 47.7% over its first seven years. Onshore farms can also perform well; the Eolo plant in Nicaragua reached 60.2% in 2015. Feasibility is not solely about the highest number; seasonality can be crucial. In Finland, for example, the capacity factor doubles in winter, aligning with high heating demand.

Hydroelectric Dam

Hydroelectric capacity factors are dictated by water availability. The Three Gorges Dam in China (22,500 MW capacity) had a capacity factor of 45% in 2015. The Hoover Dam (2,080 MW capacity) has an average annual capacity factor of about 23%, though this has fluctuated from a high of 10.3 TWh to a low of 2.6 TWh in different years, showcasing its dependence on long-term water levels in the Colorado River.

Photovoltaic Power Station

Solar PV stations have capacity factors limited by daylight hours, weather, and latitude. The Agua Caliente Solar Project in sunny Arizona (290 MW capacity) achieves a capacity factor of 29.1%. In contrast, the Lauingen Energy Park in Bavaria, Germany, located at a higher latitude with more cloud cover, has a capacity factor of just 12.0%, demonstrating the profound impact of geography on solar output.

Determinants of Capacity Factor

Technical Availability

A primary reason for a capacity factor below 100% is the plant's operational availability. Equipment can fail, and all plants require routine maintenance. This downtime accounts for most of the unused capacity in baseload power plants like nuclear, coal, and geothermal facilities, which are designed for continuous, high-efficiency operation and are difficult to ramp up and down quickly.

Economic & Market Demand

A plant's output may be intentionally reduced or shut down if electricity is not needed or if the market price is too low to justify production costs. This is the main factor for peaking and load-following plants, which are designed to respond to fluctuations in demand. A plant that only operates 12 hours a day to meet peak demand would inherently have a maximum capacity factor of 50%, making its electricity more expensive as fixed costs must be covered by limited generation.

Resource & Fuel Availability

A plant cannot operate if its energy source is unavailable. This is the defining characteristic of intermittent renewable resources like solar and wind. It also applies to hydroelectric plants during droughts or when water must be conserved. Even fossil fuel stations can be affected by restricted fuel supplies. This factor is about the availability of the "fuel," not the plant's mechanical readiness to operate.

Renewable Energy Considerations

Wind Power Variability

For wind farms, the capacity factor is a function of wind availability, the turbine's swept area, and the generator size. While the wind is naturally variable, modern wind farms achieve typical capacity factors between 25% and 45%. In regions with consistent wind, like the UK, the annual average has consistently been over 30%, with offshore wind often performing even better due to stronger, more consistent sea breezes.

Solar Energy Constraints

Solar energy is inherently variable due to the Earth's rotation, seasonal changes, and cloud cover. While a solar plant may have high technical availability, its "fuel" (sunlight) is only available for a portion of the day. In sunny regions, solar PV output can align well with summer midday peak loads caused by air conditioning. However, this peak demand often extends into the evening when solar output diminishes, highlighting a challenge for grid stability.

Hydro and Geothermal Stability

Hydroelectric plants, when water is available, are highly dispatchable, meaning they can be ramped up from a stop to full power in minutes, making them excellent for following load changes. Geothermal power stands out with one of the highest capacity factors among all energy sources, as its heat source is generally available continuously, providing a stable and reliable baseload power source comparable to nuclear or coal plants.

Capacity Factor by Source

United States Data

The U.S. Energy Information Administration (EIA) tracks the capacity factors for all utility-scale generators. The data reveals the distinct operational profiles of different technologies, from high-performing nuclear plants to intermittent renewables and dispatchable gas turbines.

Source 2013 2014 2015 2016 2017 2018
Nuclear 89.9% 91.7% 92.3% 92.3% 92.2% 92.6%
Conventional Hydro 38.9% 37.3% 35.8% 38.2% 43.1% 42.8%
Wind 32.4% 34.0% 32.2% 34.5% 34.6% 37.4%
Solar PV NA 25.9% 25.8% 25.1% 25.7% 26.1%
Solar CSP NA 19.8% 22.1% 22.2% 21.8% 23.6%
Geothermal 73.6% 74.0% 74.3% 73.9% 74.0% 77.3%
Coal 59.8% 61.1% 54.7% 53.3% 53.7% 54.0%
Natural Gas (CC) 48.2% 48.3% 55.9% 55.5% 51.3% 57.6%

United Kingdom Data

Data from the UK government illustrates the evolution of its electricity grid, showing a decline in coal utilization and a corresponding rise in the roles of natural gas and renewables. The performance of offshore wind is notably strong and consistent.

Generator Type 2007 2010 2013 2016 2019 2021
Nuclear 59.6% 59.3% 73.8% 80.1% 62.9% 58.5%
Combined Cycle Gas 64.7% 61.6% 27.9% 49.8% 43.0% 38.9%
Coal-fired 46.7% 40.2% 58.1% 21.2% 7.8% 12.7%
Hydroelectric 38.2% 24.9% 31.6% 34.0% 36.1% 33.1%
Wind Power (Total) 27.7% 23.7% 32.2% 27.8% 32.0% 29.3%
Offshore Wind 25.6% 30.5% 39.1% 36.0% 40.4% 37.4%
Photovoltaic 9.9% 7.3% 9.9% 11.0% 10.7% 10.0%
Bioenergy 52.7% 55.2% 56.8% 61.8% 55.4% 56.6%

Teacher's Corner

Edit and Print this course in the Wiki2Web Teacher Studio

Edit and Print Materials from this study in the wiki2web studio
Click here to open the "Capacity Factor" Wiki2Web Studio curriculum kit

Use the free Wiki2web Studio to generate printable flashcards, worksheets, exams, and export your materials as a web page or an interactive game.

True or False?

Test Your Knowledge!

Gamer's Corner

Are you ready for the Wiki2Web Clarity Challenge?

Learn about capacity_factor while playing the wiki2web Clarity Challenge game.
Unlock the mystery image and prove your knowledge by earning trophies. This simple game is addictively fun and is a great way to learn!

Play now

Explore More Topics

Discover other topics to study!

                                        

References

References

  1.  Hydropower, p. 441.
  2.  SREC Capacity Factor Report, https://www.masscec.com/data-and-reports
A full list of references for this article are available at the Capacity factor Wikipedia page

Feedback & Support

To report an issue with this page, or to find out ways to support the mission, please click here.

Disclaimer

Important Notice

This page was generated by an Artificial Intelligence and is intended for informational and educational purposes only. The content is based on a snapshot of publicly available data from Wikipedia and may not be entirely accurate, complete, or up-to-date.

This is not professional advice. The information provided on this website is not a substitute for professional engineering, financial, or energy policy consultation. Always refer to official documentation from regulatory bodies and consult with qualified professionals for specific project needs or investment decisions. Never disregard professional advice because of something you have read on this website.

The creators of this page are not responsible for any errors or omissions, or for any actions taken based on the information provided herein.